Lettings compliance

Gas safety certificates: duties for agents

Annual gas safety checks, the 28-day copy rule, record keeping and access problems, and how letting agents and landlords split liability when checks lapse.

Ava research teamPublished 6 min read

On this page
  1. The duty in three lines
  2. Who is liable when an agent is involved
  3. Keep the anniversary from drifting
  4. What the record must contain
  5. When the engineer finds a fault
  6. When the tenant will not give access
  7. Tenant-owned appliances and other edge cases
  8. A gas safety calendar for a managed portfolio
  9. Frequently asked questions
  10. References

Key takeaways

  • Landlords must arrange a gas safety check by a Gas Safe registered engineer every 12 months[1].
  • Give existing tenants the record within 28 days of the check and new tenants before they move in; keep records for at least two years[2].
  • A check done up to 2 months early can keep the original deadline date, which stops the anniversary drifting[2].
  • If a managing agent is used, the management contract must say who arranges checks and maintenance[1].

The duty in three lines

Gas safety in rented homes rests on three duties that every lettings team should be able to recite. Landlords must arrange an annual gas safety check, carried out every 12 months by a Gas Safe registered engineer[1]. They must give existing tenants a copy of the gas safety record within 28 days of the check, and give it to new tenants before they move in[2]. And they must keep the records for at least two years[2]. Behind those duties sits a wider obligation to keep gas appliances, flues and pipework they provide maintained in a safe condition.

The stakes are not abstract. The Health and Safety Executive says around 7 people die every year from gas-related carbon monoxide poisoning[1]. A missed anniversary is the kind of gap that turns a faulty boiler into one of those cases.

Around 7

people die every year from gas-related carbon monoxide poisoning, according to HSE[1]

Who is liable when an agent is involved

The legal duty sits with the landlord. But where a managing agent helps the landlord meet those duties, HSE says the management contract should clearly specify who is to make the arrangements for maintenance and safety checks[1]. Where the agent takes that on, the agent must arrange the work with a Gas Safe registered engineer[1]. In other words, the contract decides who carries the day-to-day duty, and an agent who has accepted it in writing will struggle to argue it was the landlord's job.

Landlords in England using agent services, 2024
Landlords in England using agent services, 2024Column chart. Agent letting services: 43%; Agent management services: 18%.0%20%40%60%Agent letting services: 43%43%Agent letting servicesAgent management services: 18%18%Agent management servicesLandlords in England using agent services, 2024Column chart. Agent letting services: 43%; Agent management services: 18%.0%20%40%60%Agent letting services: 43%43%Agent lettingservicesAgent management services: 18%18%Agent managementservices

Source: Ministry of Housing, Communities and Local Government (GOV.UK), 2024[3]

Show the data
ItemValue
Agent letting services43%
Agent management services18%

The split matters because many landlords use agents for letting only. In 2024, 43% of landlords in England used agent letting services, while 18% used agent management services[3]. A let-only landlord may assume the agent arranges annual checks because the agent arranged the first one. Close that gap in writing.

Who does what, by service level
TaskLet-onlyRent collectionFull management
First check before the tenancyAgent confirms a valid record existsAgent confirms a valid record existsAgent arranges if needed
Copy to new tenant before move-inAgent serves itAgent serves itAgent serves it
Annual checkLandlordLandlord, with agent reminder if agreedAgent arranges
Copy to existing tenant within 28 daysLandlordLandlordAgent
Repairs found at the checkLandlordLandlordAgent, within agreed spending limit
Record keepingLandlord, agent keeps a copyLandlord, agent keeps a copyAgent

Write your own version of this table into the terms of business and send it with the instruction confirmation.

Keep the anniversary from drifting

Before 2018, a check done early reset the anniversary, so dates crept earlier every year. Now landlords can have the annual check carried out up to 2 months before the date it is due and still keep the original deadline date[2]. Use that window. Book checks 6 to 8 weeks before the due date, so there is time to rebook if the tenant is away or the engineer finds a fault.

HSE adds a record-keeping condition: where you use this flexibility, keep the record until two further checks have been completed[2]. In practice that means holding at least the last three records on file.

What the record must contain

Check every record when it arrives, before you send it to the tenant. HSE lists the minimum content[2].

  • A description and location of each appliance or flue checked.
  • The name, registration number and signature of the engineer.
  • The date of the check and the property address.
  • The name and address of the landlord, or their agent where appropriate.
  • Any safety defect found and any remedial action taken.

A record that misses the engineer's registration number, or describes appliances that do not match the property, is a warning sign. Check the engineer on the Gas Safe Register and query anything unclear.

When the engineer finds a fault

A check that finds a defect is the system working, not failing, but the next 48 hours decide whether it stays that way. HSE says the record should be issued when the checks finish rather than held back while concerns are resolved, so the tenant receives it even when work is outstanding. Agree in advance with each landlord what the agency can authorise without waiting for approval, and what needs a call.

  • Immediately dangerous: the engineer will make the appliance safe, usually by disconnecting it. Call the landlord the same day and arrange a repair or temporary heating and hot water.
  • At risk: the appliance should not be used until repaired. Book the repair within days, not weeks, and tell the tenant in writing what not to use.
  • Advisory: log it, tell the landlord, and plan the work with the next maintenance visit.

Example: an engineer marks a boiler flue as at risk on a Friday afternoon in January. Under the landlord's agreed spending limit, the property manager books the repair for Monday, supplies two electric heaters that evening, and sends the tenant and landlord a written update with the record attached. The follow-up repair record goes on file next to the original.

When the tenant will not give access

Access problems are the most common reason checks lapse. HSE's position is that a landlord has to show they took all reasonable steps to comply, and its inspectors will look for at least three attempts to complete the check[1]. You must not use force to enter. Build a standard sequence and keep every message.

  1. First contact, 6 to 8 weeks ahead

    Write explaining the legal requirement and offering two or three dates, including an early morning or a Saturday if your engineer can do it.

  2. Second contact, 4 weeks ahead

    Follow up by phone and text, and confirm the agreed date in writing.

  3. Third contact, 2 weeks ahead

    If there is still no agreement, write again with a specific appointment and explain what will happen if access is not given.

  4. Visit and record

    If the engineer is turned away or nobody is in, get a written note from the engineer with the date and time.

  5. Escalate

    Tell the landlord in writing, keep trying, and take advice on the tenancy terms if the tenant continues to refuse.

Clear, early communication avoids most of these problems. The Property Ombudsman lists poor, unclear or delayed communication first among the top issues in its lettings disputes[4]. Tenants who know why the visit matters and have a choice of times usually say yes.

Tenant-owned appliances and other edge cases

Landlords are not responsible for a tenant's own gas appliance, but they do have responsibilities for parts of the associated installation and pipework[1]. If a tenant installs their own gas cooker, the landlord's check still covers the supply pipework, and the engineer may advise the tenant on the appliance.

  • New appliances provided by the landlord need a check within 12 months of installation[1].
  • HMOs and blocks with communal boilers need checks of the shared plant as well as individual appliances.
  • Properties let between tenancies still need a valid record before the next tenant moves in.
  • If the boiler is condemned, the property may still be occupied, but the tenant needs a working alternative quickly and the landlord must arrange repairs.

A gas safety calendar for a managed portfolio

Example: a lettings team managing 250 homes spreads gas checks across the year by their due dates. Each Monday the property manager runs a report of checks due in the next 60 days, books engineers for those not yet booked, and sends tenant letters for anything due in 8 weeks. Records are checked and sent to tenants on the day they arrive, with the send date logged. Once a month, the head of lettings samples five files: due date, booking attempts, record, date sent to tenant. In a year, the sample shows two late sends and no lapsed checks, and the team changes its process to send records from the engineer's portal automatically.

For electrical checks, which run on a five-year cycle with their own deadlines, see EICR: five-yearly electrical checks, and for alarms tested on the first day of a tenancy, read smoke and carbon monoxide alarm rules.

Frequently asked questions

Is a CP12 the same as a gas safety record?

CP12 is a common name for the landlord gas safety record, from an older form reference. What matters is that the record contains the information HSE requires, whatever it is called.

Can we send the gas safety record by email?

Yes, in most cases. HSE accepts electronic records that meet its conditions, so check its record-keeping guidance, and keep proof of when you sent the record to each tenant.

What if the property has no gas?

Then there is no gas safety check, but electrical safety duties and alarm rules still apply. Record on the file that the property has no gas supply, so nobody chases a record that cannot exist.

References

  1. Health and Safety Executive (2026). Domestic gas: frequently asked questions (opens in a new tab) ↑

  2. Health and Safety Executive (2026). Gas safety check records and what to keep (opens in a new tab) ↑

  3. Ministry of Housing, Communities and Local Government (GOV.UK) (2024). English Private Landlord Survey 2024: main report (opens in a new tab) ↑

  4. The Property Ombudsman (2025). Annual Review 2025 (opens in a new tab) ↑

Book a demo

See Ava handle your calls.

Book a short demo. We’ll walk through your calls and workflow, and agree what Ava should take care of.

Book a demo