Lettings compliance

Fire safety in HMOs and blocks of flats

Fire safety duties for HMOs and blocks of flats in England: responsible persons, fire risk assessments, fire doors, alarms and the 2022 regulations.

Ava research teamPublished 7 min read

On this page
  1. Two regimes that meet in shared buildings
  2. The 2022 regulations in brief
  3. The fire risk assessment for common parts
  4. Fire doors: where most problems are found
  5. Inside each unit: alarms still apply
  6. HMO licensing and fire safety
  7. A monthly fire safety routine for an HMO
  8. Taking on an HMO or block from another manager
  9. Talking to residents about fire safety
  10. Frequently asked questions
  11. References

Key takeaways

  • In multi-occupied residential buildings, the responsible person must give residents fire safety instructions and information about fire doors[1].
  • In buildings over 11 metres, communal fire doors need quarterly checks and flat entrance doors annual checks[1].
  • Inside each home, the smoke and carbon monoxide alarm rules still apply as a minimum[2].
  • A large HMO needs a licence, and the council checks it is suitable and the manager is fit and proper[3].

Two regimes that meet in shared buildings

Fire safety in shared housing sits under two overlapping regimes, and confusion between them is where agents get caught. The first is housing law, under which councils assess fire as a hazard in the home and set licence conditions for HMOs. The second is fire safety law, under which a responsible person must manage fire risk in the shared parts of a building, with the fire and rescue service as the enforcer. A converted house in multiple occupation, a block of flats above shops, and a purpose-built block can all fall under both.

For agents, the practical question is simple: who is the responsible person for the common parts, and what have they done? In many smaller HMOs and converted blocks, the landlord is the responsible person and relies on the managing agent to organise the work. In 2024, 18% of landlords in England used agent management services[4], and the HMO and block portfolios among them carry the heaviest fire safety load.

The 2022 regulations in brief

The Fire Safety (England) Regulations 2022 came into force on 23 January 2023 and added specific duties for responsible persons in multi-occupied residential buildings[1]. They are tiered by height.

Fire Safety (England) Regulations 2022 duties by building type
BuildingKey duties for the responsible person
All multi-occupied residential buildingsProvide residents with fire safety instructions and information about the importance of fire doors
Buildings over 11 metresAs above, plus quarterly checks of all communal fire doors and annual checks of flat entrance doors
High-rise buildings, at least 18 metres or 7 storeysAs above, plus a secure information box, wayfinding signage, monthly checks of firefighting lifts and electronic floor and building plans for the fire service

Each duty is set out in the government's fact sheets[1]. Measure height properly; the 11-metre threshold can catch taller converted houses and blocks of four or five storeys, not just tower blocks.

Minimum checks per year under the Fire Safety (England) Regulations 2022
Minimum checks per year under the Fire Safety (England) Regulations 2022Bar chart. Communal fire doors, buildings over 11 m: 4 checks; Flat entrance doors, buildings over 11 m: 1 checks; Firefighting lifts, high-rise buildings: 12 checks.Communal fire doors, buildings over 11 mCommunal fire doors, buildings over 11 m: 4 checks4 checksFlat entrance doors, buildings over 11 mFlat entrance doors, buildings over 11 m: 1 checks1 checksFirefighting lifts, high-rise buildingsFirefighting lifts, high-rise buildings: 12 checks12 checksMinimum checks per year under the Fire Safety (England) Regulations 2022Bar chart. Communal fire doors, buildings over 11 m: 4 checks; Flat entrance doors, buildings over 11 m: 1 checks; Firefighting lifts, high-rise buildings: 12 checks.Communal fire doors, buildings over 11mCommunal fire doors, buildings over 11 m: 4 checks4 checksFlat entrance doors, buildings over 11mFlat entrance doors, buildings over 11 m: 1 checks1 checksFirefighting lifts, high-rise buildingsFirefighting lifts, high-rise buildings: 12 checks12 checks

Source: Home Office (GOV.UK), 2023[1]

Show the data
ItemValue
Communal fire doors, buildings over 11 m4 checks
Flat entrance doors, buildings over 11 m1 checks
Firefighting lifts, high-rise buildings12 checks

The fire risk assessment for common parts

Every building with common parts needs a suitable and sufficient fire risk assessment of those parts, kept under review. For a small HMO or converted block, a competent assessor will usually look at the same handful of issues.

  1. Escape routes

    Is there a protected route from each room or flat to a final exit, free of storage, bikes and combustible items? Are stairs enclosed where the building needs them to be?

  2. Doors

    Are doors onto the escape route fire-resisting where required, with working self-closers, intact seals and no gaps? Are flat entrance doors of the right standard?

  3. Detection and alarms

    Is there an alarm system appropriate to the building, and is it tested and serviced? Are there working smoke alarms inside each unit?

  4. Lighting and signs

    Is there emergency lighting where the route needs it, and are exits clearly signed?

  5. Ignition sources

    Are electrical installations, communal heating and any cooking in rooms under control? Are smoking and charging of e-bikes managed?

  6. Information and management

    Do residents have clear instructions on what to do in a fire? Is there a log of checks, tests and repairs?

The assessment should end in an action plan with priorities and dates. Keep it with the building file and review it after any significant change, such as a refurbishment, a change of use or a fire.

Fire doors: where most problems are found

Fire doors only work when they close fully and seal. In shared houses they are also the item tenants are most likely to prop open, damage or replace with an ordinary door. Build door checks into routine inspections whether or not the building is over 11 metres.

  • Check every door on the escape route closes fully from any open position on its own.
  • Look for damaged intumescent strips, missing smoke seals and gaps around the frame.
  • Check hinges, handles and signage are intact and that no wedges or hooks hold doors open.
  • Check that flat or room entrance doors have not been swapped or altered by occupiers.
  • Record each check with the date and a photo of any defect, and fix defects quickly.

Example: a five-storey converted block of eight flats is over 11 metres. The managing agent sets a quarterly communal door inspection on the first Monday of each quarter, carried out by the cleaning contractor using a photo checklist, and an annual flat entrance door check booked with each leaseholder or tenant. Where access to a flat door is refused, the agent records each attempt and writes to the occupier, keeping the evidence on the building file.

Inside each unit: alarms still apply

Communal systems do not remove the duties inside each home. The smoke and carbon monoxide alarm rules require at least one smoke alarm on each storey with living accommodation and a carbon monoxide alarm in any room used as living accommodation with a fixed combustion appliance, excluding gas cookers[2]. In HMOs, licence conditions and council guidance usually go further, with interlinked mains-wired systems common in larger shared houses. Check the alarms on the day each new tenancy begins, as the rules require[2].

HMO licensing and fire safety

A large HMO, rented to five or more people forming more than one household who share facilities, needs a licence in England or Wales[3]. When it decides on a licence, the council checks that the house is suitable for the number of occupants and that the manager is fit and proper[3]. Fire safety is central to both judgements. Expect the council to ask for the fire risk assessment, alarm test records, the electrical report and the gas safety record, and to inspect escape routes and doors.

Smaller shared houses may also need a licence depending on the area, so check with the council[3]. Our guide to HMO licensing: mandatory, additional and selective explains the schemes.

A monthly fire safety routine for an HMO

Most HMO fire problems are management failures rather than design failures: blocked corridors, wedged doors, flat batteries. A short monthly routine prevents most of them.

  1. Walk the escape route and remove anything stored on it.
  2. Test the alarm system, or check the contractor's test log.
  3. Check fire doors close and seal, and remove any wedges.
  4. Check emergency lighting, if fitted, for faults.
  5. Look for overloaded sockets, extension leads and e-bikes charging on the escape route.
  6. Remind residents of the fire action notice and the reporting route for faults.

Log each visit and keep the log with the fire risk assessment. If a council or the fire service ever asks what you have done, a dated log answers in seconds.

Taking on an HMO or block from another manager

Handovers are when fire safety records go missing. Before you accept management of a shared building, ask for the documents and look at them, rather than assuming they exist.

  • The current fire risk assessment and its action plan, with evidence that actions were completed.
  • Alarm system test and service records, and emergency lighting records if fitted.
  • Fire door inspection records and any door replacement certificates.
  • The HMO licence, its conditions and any council correspondence.
  • The electrical report and gas safety records for each unit and for any communal plant.

Example: an agency is asked to take over a six-room HMO. The previous manager can supply the licence and gas records but no fire risk assessment. The agency makes a new assessment a condition of taking on the property, books it for the first week, and tells the landlord in writing that until it is done the fire safety position is unknown. The assessment finds two doors with missing self-closers, which are fixed within a fortnight.

Talking to residents about fire safety

Information to residents is now a legal duty in multi-occupied buildings[1], and it is also the cheapest control you have. Give every new occupier a one-page sheet at check-in: how the alarm works, why fire doors must stay shut, what to do in a fire, the evacuation strategy for the building, and how to report a fault day or night. Repeat the key points in a short message every few months and after any incident.

For alarm duties inside each unit, see smoke and carbon monoxide alarm rules, and for water safety in shared systems, legionella risk assessments for rentals.

Frequently asked questions

Who is the responsible person in a block of flats?

Usually the person or organisation in control of the common parts, such as the freeholder, the landlord or a management company. A managing agent may carry out the duties on their behalf, but the role should be agreed in writing.

Do small HMOs need a fire risk assessment?

Shared houses with common parts generally do. The depth of the assessment should match the building, and councils commonly expect one as part of licensing or inspection.

Are e-bike and e-scooter batteries a fire safety issue for HMOs?

Yes. Charging large lithium batteries in hallways or on escape routes is a growing concern. Address it in the fire risk assessment and the house rules, and give residents a safe place to charge if possible.

References

  1. Home Office (GOV.UK) (2023). Fire Safety (England) Regulations 2022 (opens in a new tab) ↑

  2. Ministry of Housing, Communities and Local Government (GOV.UK) (2022). Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022: guidance for landlords and tenants (opens in a new tab) ↑

  3. GOV.UK (2026). House in multiple occupation licence (opens in a new tab) ↑

  4. Ministry of Housing, Communities and Local Government (GOV.UK) (2024). English Private Landlord Survey 2024: main report (opens in a new tab) ↑

Book a demo

See Ava handle your calls.

Book a short demo. We’ll walk through your calls and workflow, and agree what Ava should take care of.

Book a demo